␣␣␣␣BT = 79
  1. Definition
    00117+000000000762 104BT OCT000000000762 CONSTANT USED BY LEV/RTN/FIL/BDC. LRT/092
  2. References (2)
    00000 0 00000 0 00120 3PZEBT+1 LRT/C03
    00100 0 40200 0 00117 85SUBBT FOR LOCATION RTB. LRT/073
␣␣␣␣RT = 61
  1. Definition
    00075 0 56000 1 00000 82RT LDQ**,1 OBTAIN RTB LOCATION. LRT/070
  2. References (2)
    00004 0 62100 0 00075 19START SAVE FOR 2ND TRY, IF NECESSARY= LRT/007
    00102 1 77777 1 00075 87TXIRT,1,−1 C(XR1), AND CONTINUE SEARCH. LRT/075
␣␣␣AVR = 48
  1. Definition
    00060 0 00000 0 00061 69AVR PZEQVR,,** RESTORE ORIGINAL AC OV CONDITION. LRT/057
  2. Reference
    00027 0 62200 0 00060 38SETAC STDAVR IN AVR. LRT/026
␣␣␣BAK = 32
  1. Definition
    00040 0 02100 0 00000 47BAK TTR** * EXIT TO MAIN PROGRAM. LRT/035
  2. References (2)
    00001 0 62100 0 00040 16STABAK TO CONTROL LOOP. LRT/004
    00111 1 00000 0 00040 94ERX4 TXIBAK,0,** * EXIT TO MAIN PROGRAM FOR 2ND TRY. LRT/082
␣␣␣BST = 69
  1. Definition
    00105 0 76400 0 00200 90BST BST** BACKSPACE CURRENT TAPE. LRT/078
  2. Reference
    00104 0 62100 0 00105 89STABST CURRENT TAPE ADDRESS. LRT/077
␣␣␣CHS = 17
  1. Definition
    00021 0 76000 0 00002 32CHS CHS CHANGE LTM TO ETM, AND LRT/020
  2. Reference
    00020 0 02100 0 00021 31TON TTRCHS INSTRUCTION EXECUTED IN LOCATION 1.LRT/019
␣␣␣DCR = 51
  1. Definition
    00063 0 00000 0 00000 72DCR PZE** RESTORE ORIGINAL DIVIDE CHECK COND.LRT/060
  2. Reference
    00037 0 60100 0 00063 46STODCR IN DCR. LRT/034
␣␣␣DCT = 29
  1. Definition
    00035 0 76000 0 00012 44DCT DCT RETAIN PREVIOUS LRT/032
  2. Reference
    00034 0 50000 0 00035 43CLADCT THEN LRT/031
␣␣␣LTM = 19
  1. Definition
    00023−0 76000 0 00007 34LTM LTM LEAVE TRAPPING MODE, AND LRT/022
  2. Reference
    00016 0 50000 0 00023 29CLALTM IMDE CONDITION. LRT/017
␣␣␣MAX = 77
  1. Definition
    00115+377777777777 102MAX OCT377777777777 CONSTANT USED BY LEV/RTN/FIL/BDC. LRT/090
  2. References (2)
    00056 0 56000 0 00115 67LDQMAX FORCE ALL TEST LRT/055
    00057 0 26000 0 00115 68FMPMAX CONDITIONS ON, AND THEN LRT/056
␣␣␣NOP = 52
  1. Definition
    00064 0 76100 0 00000 73NOP NOP AND THEN LRT/061
  2. References (3)
    00024 0 50000 0 00064 35CLANOP THEN LRT/023
    00030 0 50000 0 00064 39CLANOP THEN LRT/027
    00036 0 50000 0 00064 45CLANOP DIVIDE CHECK CONDITION LRT/033
␣␣␣NXT = 50
  1. Definition
    00062 0 22100 0 00116 71NXT DVPZER AND THEN LRT/059
  2. Reference
    00061 0 00000 0 00062 70QVR PZENXT,,** RESTORE ORIGINAL MQ OV CONDITION. LRT/058
␣␣␣QVR = 49
  1. Definition
    00061 0 00000 0 00062 70QVR PZENXT,,** RESTORE ORIGINAL MQ OV CONDITION. LRT/058
  2. References (2)
    00033 0 62200 0 00061 42SETMQ STDQVR IN OVR. LRT/030
    00060 0 00000 0 00061 69AVR PZEQVR,,** RESTORE ORIGINAL AC OV CONDITION. LRT/057
␣␣␣RES = 41
  1. Definition
    61 RES = ENTRY POINT USED BY (FIL). LRT/049
    00051−0 50000 0 00112 62RES CALC(0) RESTORE LRT/050
␣␣␣RET = 54
  1. Definition
    00066 0 02100 0 00000 75RET TTR** * EXIT TO MAIN PROGRAM. LRT/063
  2. Reference
    00043 0 62100 0 00066 55STARET TO CONTROL LO0P. LRT/043
␣␣␣RTM = 53
  1. Definition
    00065 0 00000 0 00000 74RTM PZE** RESTORE ORIGINAL TRAP MODE COND. LRT/062
  2. Reference
    00022 0 60100 0 00065 33SET STORTM SET RTM TO RESTORE TRAPPING COND. LRT/021
␣␣␣SET = 18
  1. Definition
    00022 0 60100 0 00065 33SET STORTM SET RTM TO RESTORE TRAPPING COND. LRT/021
  2. Reference
    00017 1 00000 0 00022 30ERX1 TXISET,0,** IF IN TRAPPING MODE, THEN LRT/018
␣␣␣TON = 16
  1. Definition
    00020 0 02100 0 00021 31TON TTRCHS INSTRUCTION EXECUTED IN LOCATION 1.LRT/019
  2. Reference
    00014−0 50000 0 00020 27CALTON SET UP FOR LRT/015
␣␣␣TOV = 21
  1. Definition
    00025 0 14000 0 00027 36TOV TOVSETAC RETAIN PREVIOUS LRT/024
  2. Reference
    00026 0 50000 0 00025 37CLATOV AC OVERFLOW CONDITION LRT/025
␣␣␣TQO = 25
  1. Definition
    00031 0 16100 0 00033 40TQO TQOSETMQ RETAIN PREVIOUS LRT/028
  2. Reference
    00032 0 50000 0 00031 41CLATQO MQ OVERFLOW CONDITION LRT/029
␣␣␣TRY = 55
  1. Definition
    D00067−3 00000 0 00072 76TRY TXLTRY1,0 OPSWITCH (TXL=TRA, TXH=NOP). LRT/064
  2. References (3)
    00046 1 00000 0 00067 58ERX2 TXITRY,0,** CORRECT, THEN TRY AGAIN. LRT/046
    00050 0 63000 0 00067 60STPTRY SET TRY TO TRANSFER CASE. LRT/048
    00073 0 63000 0 00067 80STPTRY FOR 2ND ATTEMPT AT READING RECORD. LRT/068
␣␣␣ZER = 78
  1. Definition
    00116 0 00000 0 00000 103ZER PZE0 CONSTANT USED BY LEV/RTN/FIL/BDC. LRT/091
  2. References (2)
    00062 0 22100 0 00116 71NXT DVPZER AND THEN LRT/059
    00074 0 53400 1 00116 81LXAZER,1 SET XR1 = 0, AND LRT/069
␣␣C(0) = 74
  1. Definition
    95 END OF PROGRAM (RTN). LRT/083
    96* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *LRT/084
    97 LRT/085
    98CONSTANTS AND WORKING STORAGE USED BY LEV/RTN/FIL/BDC. LRT/086
    00112 0 00000 0 00000 99C(0) PZE** VARIABLE USED BY LEV/RTN/FIL/BDC. LRT/087
  2. References (2)
    00011 0 60200 0 00112 24SLWC(0) CONTENTS OF LOCATION 0, LRT/012
    00051−0 50000 0 00112 62RES CALC(0) RESTORE LRT/050
␣␣C(1) = 75
  1. Definition
    00113 0 00000 0 00000 100C(1) PZE** VARIABLE USED BY LEV/RTN/FIL/BDC. LRT/088
  2. References (2)
    00013 0 60200 0 00113 26SLWC(1) CONTENTS OF LOCATION 1. LRT/014
    00053−0 50000 0 00113 64CALC(1) RESTORE LRT/052
␣␣CONT = 67
  1. Definition
    00103−0 76300 0 00030 88CONT LGL24 WHEN FOUND, SET LRT/076
  2. Reference
    00101 0 10000 0 00103 86TZECONT IF NOT, THEN ADJUST THE LRT/074
␣␣ERX1 = 15
  1. Definition
    00017 1 00000 0 00022 30ERX1 TXISET,0,** IF IN TRAPPING MODE, THEN LRT/018
  2. References (2)
    00005−0 63400 1 00017 20SXDERX1,1 STARTING LOCATION, AND THE LRT/008
    00106−0 53400 1 00017 91LXDERX1,1 RESTORE THE LRT/079
␣␣ERX2 = 38
  1. Definition
    00046 1 00000 0 00067 58ERX2 TXITRY,0,** CORRECT, THEN TRY AGAIN. LRT/046
  2. References (2)
    00006−0 63400 2 00046 21SXDERX2,2 CONTENTS OF XR1, XR2, LRT/009
    00107−0 53400 2 00046 92LXDERX2,2 ORIGINAL CONTENTS 0F LRT/080
␣␣ERX4 = 73
  1. Definition
    00111 1 00000 0 00040 94ERX4 TXIBAK,0,** * EXIT TO MAIN PROGRAM FOR 2ND TRY. LRT/082
  2. References (2)
    00007−0 63400 4 00111 22SXDERX4,4 AND XR4. LRT/010
    00110−0 53400 4 00111 93LXDERX4,4 XR1,XR2, AND XR4. LRT/081
␣␣GOOD = 39
  1. Definition
    00047−0 50000 0 00071 59GOOD CALTXLOP OTHERWISE, CONTINUE. LRT/047
  2. Reference
    D00071−3 00000 0 00047 78TXLOP TXLGOOD,0 PRESS START TO ACCEPT RECORD. LRT/066
␣␣L(2) = 76
  1. Definition
    00114 0 00000 0 00002 101L(2) PZE2 CONSTANT USED BY LEV/RTN/FIL/BDC. LRT/089
  2. References (2)
    00000 0 40000 0 00114 15(LEV) ADDL(2) SET UP FOR RETURN LRT/003
    00042 0 40000 0 00114 54ADDL(2) SET UP FOR RETURN LRT/042
␣␣TRY1 = 58
  1. Definition
    00072 0 50000 0 00071 79TRY1 CLATXLOP SET TRY TO NO TRANSFER CASE LRT/067
  2. Reference
    D00067−3 00000 0 00072 76TRY TXLTRY1,0 OPSWITCH (TXL=TRA, TXH=NOP). LRT/064
␣(LEV) = 0
  1. Definition
    13(LEV)/ CALLER=MAIN PROGRAM. LRT/001
    14(LEV) SAVES ALL INDICATORS BEFORE I/O TRANSMISSION. LRT/002
    00000 0 40000 0 00114 15(LEV) ADDL(2) SET UP FOR RETURN LRT/003
  2. Reference
    00003 0 00000 0 00000 6PZE(LEV) LRT/C06
␣(RTN) = 33
  1. Definition
    48 END OF PROGRAM (LEV). LRT/036
    49* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *LRT/037
    50 LRT/038
    51(RTNI/ CALLERS=MAIN PROGRAM,(FIL). LRT/039
    52(RTN) RESTORES ALL INDICATORS AFTER I/O TRANSMISSION. LRT/040
    00041−0 76000 0 00007 53(RTN) LTM LEAVE TRAPPING MODE, AND LRT/041
  2. Reference
    00005 0 00000 0 00041 8PZE(RTN) , LRT/C08
␣SETAC = 23
  1. Definition
    00027 0 62200 0 00060 38SETAC STDAVR IN AVR. LRT/026
  2. Reference
    00025 0 14000 0 00027 36TOV TOVSETAC RETAIN PREVIOUS LRT/024
␣SETMQ = 27
  1. Definition
    00033 0 62200 0 00061 42SETMQ STDQVR IN OVR. LRT/030
  2. Reference
    00031 0 16100 0 00033 40TQO TQOSETMQ RETAIN PREVIOUS LRT/028
␣TXLOP = 57
  1. Definition
    D00071−3 00000 0 00047 78TXLOP TXLGOOD,0 PRESS START TO ACCEPT RECORD. LRT/066
  2. References (2)
    00047−0 50000 0 00071 59GOOD CALTXLOP OTHERWISE, CONTINUE. LRT/047
    00072 0 50000 0 00071 79TRY1 CLATXLOP SET TRY TO NO TRANSFER CASE LRT/067